Page 29 1330SE - Operator’s Manual
June 2023Section 9 - Maintenance
Lubrication
Operator may perform routine maintenance only. Lubrication listed as Scheduled Maintenance must
be performed by a qualied service technician.
ART_5000
Hydraulic
Unit
FULL
Component
Tray
ADD
No. Item Specication Frequency
1 Hydraulic Reservoir
Mobile Fluid DTE 10, DTE 13 M, or AW32
Do not substitute other uids as pump
damage may result.
Fill to the middle of the dipstick with
platform in the stowed position.
Routine Maintenance
Check hydraulic oil level every week
Scheduled Maintenance
Change yearly or every 600 hours,
whichever occurs rst
2
Hydraulic Cap
Breather Filter
Breather Filter
(Located inside Filler Cap)
Scheduled Maintenance
Normal Conditions
Change every six months or 300 hours,
whichever occurs rst
Severe Conditions--very dusty,
exceptionally hot or exceptionally cold
conditions
Change every three months or 150 hours,
whichever occurs rst