Page 18 65-J Diesel - Operator’s Manual
September 2022Section 7 - Operating Instructions & Pre-Operation Function Tests
Move the Start/Stop switch upward to start. Release the switch when the
engine starts.
The light will turn on when the Kubota ECU determines it necessary to activate
glow plugs before starting the engine.
This light has 2 functions.
1. To protect the starter motor, power cuts o to the starter circuit when the
starter motor has run continuously for 10 seconds without starting the
engine. The Starter Circuit Cutout indicator light on the Lower Controls
Box will turn on during this time. Power to the starter circuit reengages
after 30 seconds.
2. Functions as Engine ECU Fault Code indicator. The light will Flash
Engine Fault Code.
Starting Engine from Platform Controls
Lower Control Box: Turn the Key Switch to PLATFORM.
Platform Control Box: Move the Start/Stop switch UP to start. Release the
switch when the engine starts.