Page 42 65-J Diesel - Operator’s Manual
September 2022Section 8 - Machine Inspections and Maintenance
Lubrication
Operator may perform routine maintenance only. Lubrication listed as Scheduled Maintenance must
be performed by a qualied service technician.
LEVEL
Hydraulic Fluid
Sight Gauge
3
1
2
components removed
for clarity
No. Item Specication Frequency
1
Hubs
SAE 90 Multipurpose Hypoid Gear Oil
API Service Classication GL5
Scheduled Maintenance
Check every three months or 150 hours, whichever
occurs rst.
Change yearly or every 600 hours, whichever occurs
rst.
2
Hydraulic
Reservoir
Fluid Type
Chevron 1000THF
Chevron Rando Premium MV
Temperature Range
> 30° F (0° C)
< 30° F (0° C)
Routine Maintenance
Check level daily
Scheduled Maintenance
Change yearly or every 600 hours, whichever occurs
rst
Do not substitute other uids as pump damage may
result.
Fill to the middle of the sight gauge with platform in the
stowed position.
3
Hydraulic
Filter
Filter Element (located inside Hydraulic Reservoir)
Scheduled Maintenance
Normal Conditions
Change every six months or 300 hours, whichever
occurs rst
Severe Conditions -- very dusty, exceptionally hot
or exceptionally cold conditions
Change every three months or 150 hours, whichever
occurs rst