Page 42 65-J Diesel - Operator’s Manual
September 2022Section 8 - Machine Inspections and Maintenance
Lubrication
Operator may perform routine maintenance only. Lubrication listed as Scheduled Maintenance must
be performed by a qualied service technician.
ART_4736
LEVEL
Add Oil Here
Hydraulic Fluid
Sight Gauge
Fill to Here
3
1
2
Controls Module
components removed
for clarity
No. Item Specication Frequency
1
Hubs
SAE 90 Multipurpose Hypoid Gear Oil
API Service Classication GL5
Scheduled Maintenance
Check every three months or 150 hours, whichever
occurs rst.
Change yearly or every 600 hours, whichever occurs
rst.
2
Hydraulic
Reservoir
Fluid Type
Chevron 1000THF
Chevron Rando Premium MV
Temperature Range
> 30° F (0° C)
< 30° F (0° C)
Routine Maintenance
Check level daily
Scheduled Maintenance
Change yearly or every 600 hours, whichever occurs
rst
Do not substitute other uids as pump damage may
result.
Fill to the middle of the sight gauge with platform in the
stowed position.
3
Hydraulic
Filter
Filter Element (located inside Hydraulic Reservoir)
Scheduled Maintenance
Normal Conditions
Change every six months or 300 hours, whichever
occurs rst
Severe Conditions -- very dusty, exceptionally hot
or exceptionally cold conditions
Change every three months or 150 hours, whichever
occurs rst