Page 34 65-J Diesel - Operator’s Manual
September 2022Section 7 - Operating Instructions & Pre-Operation Function Tests
the platform, activate the Auxiliary Power Switch to run the auxiliary hydraulic pump.
This function uses battery power from the auxiliary battery to lower the platform.
• Push and hold the Auxiliary Power Switch, then use the Boom Extend/Retract function to retract
the boom.
• Continue to hold the Auxiliary Power Switch, then use the Boom Lift/Lower function to lower the
boom.
Note: Auxiliary Power activation stops the engine.
Note: The Auxiliary Power Switch serves as an enable switch. It is not necessary to use the primary
function enable switch.
Test Operation
• Test the Auxiliary Power System from both control stations.
• Test any lift function for 5-10 seconds to verify proper operation.