Page #31 background image
www.megger.com
31
International model variations:
Continuity retest after fail (PAT120, PAT150 DE, & CH models only)
When a continuity test fails to meet the pre-set continuity resistance pass limit of 0.3 W, the test can be run again within 5 seconds at the higher 1.0 W limit.
Example Class I continuity FAIL. Display shows:
to retest at 1.0 W limit or
to FAIL test