EasyManuals Logo

Megmeet MV600L Series User Manual

Megmeet MV600L Series
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
28
E: Reserved (command rate
numerator)
Tens place of LED: AI2 function
selection is the same as above
Hundreds place of LED: AI3
function selection is the same as
above
Group P11: Auxiliary function parameters
P11.00
Accelerati
on/
decelerati
on mode
selection
Acceleration
/
deceleration
mode
selection
0: Linear acceleration/deceleration
1: S curve
acceleration/deceleration
1 0 × ×
P11.02
Accelerati
on time 2
Acceleration
time 2
0.0~3600.0
(Unit
adopts
that of
P11.01)
0.1
6.00 ×
P11.03
Decelerati
on time 2
Deceleration
time 2
0.0~3600.0
(Unit
adopts
that of
P11.01)
0.1
6.00 ×
P11.14
Switching
frequency
of
accelerati
on/
decelerati
on time 1
and 2
Switching
frequency of
acceleration
/
deceleration
0.00~3000.00Hz 0.01Hz 0.00 ×
P11.15
Switching
hysteresis
loop
frequency
of
accelerati
on/
decelerati
on time 1
and 2
Switching
hysteresis
loop
frequency of
acceleration
/
deceleration
0.00~655.35Hz 0.01Hz 1.00 ×
P11.16
Jog
accelerati
on
/decelerati
on time
Jog
acceleration
/deceleratio
n time
0.1~60.0s 0.1s 6.0 ×
P11.17
Jog
interval
Jog interval
0.0~100.0s 0.1s 0.0 ×
P11.18
Frequency
of jog
Frequency
of jog
0.10~50.00Hz 0.01Hz 5.00

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Megmeet MV600L Series and is the answer not in the manual?

Megmeet MV600L Series Specifications

General IconGeneral
BrandMegmeet
ModelMV600L Series
CategoryDC Drives
LanguageEnglish

Related product manuals