62 
 
Fault 
code 
Fault type  Possible fault cause  Solutions 
When reverse running is prohibited, 
reverse rotating auto-tuning is 
performed. 
Cancel the reverse running prohibition 
Auto-tuning overtime 
Check motor wiring 
Check the P02.16 (upper limit frequency) and see 
whether the P02.17 set value is lower than rated 
frequency. 
Er.PG1 PG fault 
With PG vector control (or with PG V/F 
control), the encoder signal 
disconnects. 
Check the encoder wiring and rewiring 
Er.PST 
Parameter 
setting error 
Wrong speed feedback encoder 
selection setting 
The same speed feedback encoder shall not be 
used for two motors simultaneously.   
Wrong analog AI function selection 
setting  
The same function shall not be selected for different 
analogs simultaneously.   
Process closed loop invocation setting 
error 
During vector control, the torque limit (P05.13,
P05.14) and frequency reference (P02.04 or PLC 
section frequency reference) can not be given by 
the process closed loop simultaneously. 
Lifting application type error 
Lifting application type that is P00.07 = 2 for 
non-vector control mode   
Er.24v 
Control board 
24V power short 
circuit  
Short circuit of P24 and terminal COM 
Confirm whether the wiring of P24 and COM is 
correct  
The interface board circuit is damaged.
Replace the interface board, seek for service 
support 
Er.oPT 
Expansion card 
fault  
The expansion card is poorly inserted.  Reinsert the expansion card   
The expansion card is damaged.    Seek for service support 
Er.GdF 
Grounding short 
circuit fault   
One of the phases (The most likely one 
is phase U) is grounding short circuited. 
Check the grounding short circuit of the output 
three phase and troubleshoot it.   
Er.dEv 
Too large speed 
deviation (DEV) 
fault  
ASR parameters are improper.  Modify the setting of the group P05 function code 
DEV deviation detection value setting is 
too low. 
Modify the DEV detection value setting 
Heavy load fluctuation  Eliminate the load vibration 
Er.oHL 
Motor 
over-temperature 
The ambient temperature is too high.  Lower the ambient temperature 
The motor duct is blocked.    Clean the motor duct