6. UPDATING SOFTWARE
Every new SCR® Recycler supplied from CPI© contains “blank” (or vanilla) software.
As such, it will not function in normal operational conditions. Therefore, all software
for the SCR device (application code and required variant/billset) must to be
programmed prior to use. There are three methods in which to perform software
updates for SCR:
1. Cashflow® STS software tool
2. Field programming module called PPM Advance
3. Protocol specific commands via software packages trough Serial (RS232) or
USB (optional) interface
Please note that an un-programmed unit will not communicate via serial
interface. The MMI panel will illuminate all 3 LEDs and flash simultaneously.
6.1 USING CASHFLOW STS TOOL FOR SOFTWARE UPDATE
Cashflow® STS support tool version 7.10 or higher is required for updating SCR
software. This tool also requires a license key, which can be from the CPI Technical
Support team, upon request. More information about the Cashflow® STS installation
can be found in STS User Manual.
Ensure that the correct USB drivers are installed for the SCR prior to use. Connect
to the SCR via the front USB port on the SCN acceptor head. Successful connection
will reveal a highlighted “Read” button and the SCR device Serial Number will
populate on the lower portion of the window (Image 37)