9 Technical Appendix
output voltage: 1.5 V eff.
output impedance: 200 Ohm
Serial Ports: 2 asynchronous serial ports RS-232 (optional max. 4 serial ports)
Baud Rate: 300, 600, 1200, 2400, 4800, 9600, 19200 Baud
Framing: 7E1, 7E2, 7N2, 7O1, 7O2, 8E1, 8N1, 8N2, 8O1
default setting:
COM0: 19200, 8N1
Meinberg Standard time string, per second
Time Code Outputs: Unbalanced modulated sine wave signal:
3 Vpp (MARK), 1 Vpp (SPACE) into 50 ohm
DCLS-signal: TTL into 50 ohm, active-high or -low
microSync Date: 17th June 2020 35