EasyManua.ls Logo

Meinberg SyncFire 1200 - 12 Attachment: Technical Information; 12.1 Technical Specifications SyncFire 1200

Meinberg SyncFire 1200
55 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12 Attachment: Technical Information
12.1 Technical Specifications SyncFire 1200
Dimensions: [W x H x D] 43.46 x 4.29 x 61.49 cm (17.11 x 1.69 x 24.21 in)
Mounting Depth Rack: 620 mm
Height Unit Rack: 1 U
19 inch Rackmount: Yes
Mounting Cable Depth: 200 mm (1000 mm rack recommended)
Weight: 10 kg (22.05 lb)
Electrical data (hot-plug power supply unit)
Rated Line Voltage: 100 to 120 V AC (200 to 240 V AC)
Frequency: 50/60 Hz
Effective Power: 500 W
Max. Thermal energy: (for 500 W power supply:)
2088 kJ/hr (1979 BTU/hr) at 100 V AC
2016 kJ/hr (1911 BTU/hr) at 200 V AC
2073 kJ/hr (1965 BTU/hr) at 240 V AC
Power Supply Configuration: 2 x hot-plug power supply for redundancy
Standard Operating
Temperature: 10
to 35
C (50
to 95
F) at sea level with an altitude derating of 1.0
C
per every 305 m (1.8
F per every 1000 ft) above sea level to a maximum of
3050 m (10,000 ft). Maximum rate of change is 20
C/hr (36
F/hr).
Non Operating
Temperature: -30
to 60
C (-22
to 140
F). Maximum rate of change is 20
C/hr (36
F/hr).
Relative Humidity: Operating
10 % ... 85 % (non condensing)
Non-operating
5 to 95 % relative humidity (Rh), 38.7
C (101.7
F)
maximum wet bulb temperature, non-condensing.
Altitude: Operating
3050 m (10,000 ft). This value may be limited by the type and number of options
installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude change rate is
457 m/min (1500 ft/min).
Source: Hewlett Packard documentation: HPE-ProLiant-DL325-Gen10
42 Date: 31st March 2021 SyncFire 1200