EasyManua.ls Logo

Merak MEP2L - Test call protocol; Test call attempts; Identifier for P100; Time between test calls

Default Icon
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MEP2L
EMERGENCY TELEPHONE FOR LIFTS
Rev. M2.4 © Merak. All rights reserved
Command Manual · Voice Mode 10 for 22
Test call protocol
This parameter sets the protocol to be used in the test call for each phone number. It is
recommended to use P100 protocol, which is the default protocol.
Test call attempts
This parameter sets the maximum number of turns the algorithm gives to the test call number
table to get a valid call. The minimum is 1 and the maximum 3. If two different numbers are
programmed for test calls, the maximum number of attempts will be six.
Identifier for P100
The test protocol at P100 is extremely simple. The phone calls the test server, it picks up and
answers with one character, the phone answers with the 8-character long identifier
encapsulated in a checksum frame, and if the reception is correct, the test is good. The
identifier must be unique in the phone park managed by a P100 test server. The administrator
of the P100 test server must manage the assignment of length 8 identifiers.
Time between test calls
This parameter sets the time between test calls, expressed in minutes. The minimum accepted
value is 1440 minutes (one day)
MEMORY
PROGRAMMING
REMARKS
46
*46#TelTest1_protocol
0: Merak Protocol 1: P100
47
*47#TelTest2_protocol
0: Merak Protocol 1: P100
MEMORY
PROGRAMMING
REMARKS
21
*21#n
N = 1, 2 or 3 Default value 1
COMMAND
ACTION
REMARKS
*3#xxxxxxxx
Programming Identifier
Use digits from 0 to 9
*3*
Consult identifier
COMMAND
PROGRAMMING
REMARKS
*24#n
Schedule test time
The time in minutes, default value
4320 min (72 hours), minimum
1440 min
*24*
Consult test time