MAINTENANCE
90-855347R1 JANUARY 1999 Page 1B-9
Compressor Air intake Filter
The filter should be changed every 100 hours of operation, or once a season. Never run
the engine without the air filter.
Removal
1. Remove flywheel cover from the engine. Snap out the retainer (a) and remove filter
(b).
a
b
Installation
Install filter (b) into the cover. Secure filter into cover with retainer (a).
Lubrication Points
Lubricate Point 1 with Quicksilver Special Lubricant 101.
1. Trim Rod Ball Ends – Turn the ball ends to work the lubricant into the ball sockets.
1