OPERATION MANUAL
6.3 CHANGING OIL
Cover
Oil Level Indicator
1. Remove the oil tank cover.
2. Using an appropriate pump, drain out the old oil completely. Be sure nothing is le
3. Using a pump, ll the tank with new 46 grade hydraulic oil until the oil reaches the top mark of
the oil indicator. Check the oil level regulary to make sure it is always kept at the same level.
4. When changing oil, keep the oil tank clean and free of dirt at all times..
5. Oil must be changed aer rst 200 working hours of use, and then aer every 1000 working hours.
(See: Lubrication Diagram) .
e eciency of the Metalmaster machine relies on the hydraulic system being well maintained
All precautions must be taken to keep the hydraulic system clean at all times.
4.4 CHANGING THE FILTER
1. Remove the cover on the oil tank.
2. Unscrew the old lter from its place inside the oil tank.
3. Screw the new lter into its place in the tank and replace the cover. (Fig 6.6)
Note ! e suction lter element must be cleaned aer rst 200 hours of use, and then aer every
1000 working hours. Replace if damaged.
Fig. 6.6 Cover
07/11/2019
Instructions Manual for PB-460 (S581B)
21

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MetalMaster PB-830T and is the answer not in the manual?

MetalMaster PB-830T Specifications

General IconGeneral
BrandMetalMaster
ModelPB-830T
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals