    Jacob ParkerAug 19, 2025
    What to do if the METER Measuring Instruments control unit shows low battery?
    • D
      David StoneAug 19, 2025
      This error appears when the battery voltage drops below the minimum voltage required for the water pump to operate (11.1 V) during a test, which then stops the test. To resolve this, ensure the battery is fully charged by charging it.
  • R
    robert61Aug 21, 2025
    What to do if the METER Measuring Instruments infiltrometer does not maintain pressure?
    • D
      David KingAug 21, 2025
      If the infiltrometer does not maintain pressure, try the following: 1. Remove the infiltrometer head and check for any debris (such as grass, leaves, or loose soil) where the gasket seals with the insertion ring. 2. Check the tightness of the clamps, ensuring they apply only enough pressure to slightly compress the gasket. 3. Inspect tubing connections to ensure tubes are fully inserted into the push-to-connect fittings.
  • K
    kramerlindaAug 23, 2025
    What to do if the METER Measuring Instruments shows 'Pressure limit exceeded!'?
    • J
      Johnathan MurilloAug 23, 2025
      The 'Pressure limit exceeded!' error occurs when the air pressure in the chamber is over 60.0 cm or below ?50.0 cm, which stops the test. To fix this, check the tubing for any kinks or blockages that may be causing the pressure issue.
  • S
    Sean KingAug 26, 2025
    What to do if the METER Measuring Instruments temperature is too high?
    • J
      Jamie VasquezAug 26, 2025
      The 'Temperature too high!' error appears when the air temperature exceeds the maximum operating temperature (50 °C) during a test, causing the test to stop. To resolve this, move the system to a cooler environment, ensuring it is out of direct sunlight. Once cooled, power the system off and then on again to clear the message.
  • M
    Melissa WatkinsAug 28, 2025
    What to do if the METER Measuring Instruments temperature is too low?
    • J
      John RodriguezAug 28, 2025
      The 'Temperature too low!' error occurs when the air temperature falls below the minimum operating temperature (0 °C) during a test, which can cause damage due to water freezing in the system and will stop the test. To fix this, move the system to a warmer environment. After the system has warmed up, turn the power off and on again to clear the message.
  • R
    Roger BallardAug 30, 2025
    What to do if the METER Measuring Instruments test failed to reach the target water level?
    • P
      Paul KaufmanAug 30, 2025
      If a test fails to reach the target water level, check for leaks around the seal of the infiltrometer head.
  • M
    mccallmarkSep 1, 2025
    What to do if METER Measuring Instruments control unit becomes unresponsive?
    • R
      Robin SimmonsSep 1, 2025
      If the control unit becomes unresponsive, press and hold the BACK button for more than 7 seconds to restart it.
  • J
    jeffrey34Sep 4, 2025
    What to do if METER Measuring Instruments shows 'Water level error!'?
    • K
      Kelsey McfarlandSep 4, 2025
      If you encounter a 'Water level error!', check that the water supply is connected and that water can easily flow from the water supply through the control unit into the infiltrometer head.
  • J
    Jennifer HernandezSep 6, 2025
    What to do if the METER Measuring Instruments date and time were reset?
    • S
      Shari FisherSep 6, 2025
      If the date and time were reset, ensure the battery is fully charged and update the date and time in the Settings menu.
  • F
    fernandezanthonySep 8, 2025
    What to do if METER Measuring Instruments shows 'Selected pressure heads are not being reached'?
    • B
      Bradley FullerSep 8, 2025
      If the selected pressure heads are not being reached and there are no apparent leaks, and if the SATURO is on a slope that may be too great, preventing the water level from reaching the sensor, try sampling a new location or adding a second water supply to proceed with the measurements.

Summary

1. INTRODUCTION

2. OPERATION

2.1 INSTALLATION

Steps to set up the SATURO infiltrometer, including preparing the site and connecting components.

2.2 FUNCTIONALITY

Overview of how to use the SATURO for data collection, including setting up tests.

2.2.1 SETTING UP A TEST

Detailed steps for naming and configuring test parameters on the SATURO control unit.

2.2.2 STARTING A TEST

Instructions for initiating a measurement test on the SATURO, including pre-test checks.

2.2.3 STOPPING A TEST

Procedure for safely stopping an ongoing SATURO test.

2.2.4 DOWNLOADING DATA

Steps for connecting the SATURO to a computer and downloading measurement data.

3. SYSTEM

3.1 SPECIFICATIONS

Technical specifications of the SATURO infiltrometer, including measurement ranges and physical properties.

3.2 COMPONENTS

Description and illustration of the SATURO system's main components.

3.2.1 CONTROL UNIT

Details on the SATURO control unit, its buttons, navigation, and display screens.

3.2.2 INSERTION RING

Details on the SATURO insertion rings, including their depths and applications.

3.2.3 INFILTROMETER HEAD

Description of the SATURO infiltrometer head, its sensors, and connections.

3.2.4 WATER SUPPLY TANK

Information on the SATURO water supply tank capacity and its use.

3.3 THEORY

Explanation of the theory behind field saturated hydraulic conductivity measurement using SATURO.

4. SERVICE

4.1 CALIBRATION

Procedures for calibrating the SATURO water pump using mass or volume methods.

4.2 MAINTENANCE

Guidelines for cleaning and maintaining the SATURO infiltrometer after each use.

4.3 TROUBLESHOOTING

Common problems encountered with SATURO and their possible solutions.

4.4 CUSTOMER SUPPORT

Contact information and procedures for obtaining customer service and technical support.

4.5 TERMS AND CONDITIONS

Legal terms and conditions governing the purchase and use of the SATURO instrument.

METER SATURO Specifications

General IconGeneral
BrandMETER
ModelSATURO
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals