1.4 Electrical connection
Electrical connection must be carried out in compliance with the legislation in force and the relevant technical standards.
Make sure that the voltage is the same as reported on the data-plate.
It is necessary to install a suitable omni-polar automatic fuse switch sized according to the absorption that assures
the complete disconnection from the network in an overvoltage category III condition.
This switch must be incorporated in the supply network, dedicated only and exclusively to this circuit and installed in
the immediate vicinity.
The machine has to be absolutely turned off by this switch: only this switch gives the full warranty of complete
detachment from the electric network.
Make sure the appliance is linked to an efficient ground connection.
The machine is also provided with a terminal (marked with the symbol ) placed on the back end. It shall be used to
bond different appliances via the external bonding conductor, in order to avoid the risk of electric shock.
ATTENTION: Check very carefully if the “ground connection” of the machine is properly sized and fully
efficient, and that not too many units are connected to it. An undersized or poor “ground connection”
might lead to corrosion and/or pitting effect on the stainless steel plates, even to perforation.
Feed cable: The retailer - importer - installer must ensure that the feed cable complies with the cable
insulation category of the workplace, in conformity with current Technical Standards.