Do you have a question about the Microlife BP B2 Basic and is the answer not in the manual?
Type | Automatic |
---|---|
Cuff size | 22 - 42 cm |
Control type | Buttons |
Product color | White |
Number of users | 1 user(s) |
Measuring method | Oscillometric |
Memory registers | 30 |
Pulse rate range | 40 - 200 |
Speaking function | No |
Placement supported | Upper arm |
Units of measurement | mmHg |
Mean arterial pressure | Yes |
Display type | LCD |
Battery type | AA |
Battery voltage | 1.5 V |
Battery technology | Alkaline |
Battery life (CIPA standard) | 920 shots |
Number of batteries supported | 4 |
Quantity per pack | 1 pc(s) |
Pressure accuracy | 1 mmHg |
Pressure measurement range | 20 - 280 mmHg |
Depth | 90 mm |
---|---|
Width | 131 mm |
Height | 60.5 mm |
Weight | 277 g |
Sit on a back-supported chair and keep your legs uncrossed.
Avoid thick or close-fitting garments on the upper arm.
Place the artery-mark on the cuff over your artery.
Fit the cuff closely, but not too tight.
Position the cuff 1-2 cm above your elbow.
Keep your arm still and do not speak during the measurement.
Avoid eating, smoking, caffeine, and relax for 5-10 minutes.
Measure before medication intake.
For measuring non-invasive blood pressure in people aged 12 years or older.
Follow instructions, handle with caution, and keep away from children.
Insert batteries (4x1.5V AA) into the compartment, observing polarity.
Set year, month, day, hour, and minutes using the buttons.
Choose the appropriate cuff size for your upper arm circumference.
Avoid activity, relax, sit correctly, keep feet flat, measure on same arm.
Ensure correct cuff fit, position 1-2 cm above elbow, artery alignment.
Press ON/OFF, relax, and wait for the automated measurement result.
Understand display symbols and pressure ranges (normal, elevated, high).
Press M-button to cycle through the last 30 measurements.
Hold M-button to permanently clear all stored values.
Replace batteries when the low battery symbol appears.
Use AA alkaline or NiMH rechargeable batteries; remove for long storage.
Connect adapter to device and wall socket; no battery consumed.
Understand error codes (ERR 1-5, HI, LO) and their remedies.
Do not use for pediatric patients or with certain limb conditions.
Avoid damage, keep away from children, and protect limbs from pressure.
Hand wash cuff cover in soapy water (max 30°C).
Test accuracy every 2 years; dispose of batteries/device correctly.
5-year guarantee for device, 2-year for cuff bladder tightness.