8
Should guarantee service be required, please contact the dealer
from where the product was purchased, or your local Microlife
service. You may contact your local Microlife service through our
website:
www.microlife.com/support
Compensation is limited to the value of the product. The guarantee
will be granted if the complete product is returned with the original
invoice. Repair or replacement within guarantee does not prolong
or renew the guarantee period. The legal claims and rights of
consumers are not limited by this guarantee.
10.Technical specifications
This device complies with the requirements of the Medical Device
Directive 93/42/EEC.
Technical alterations reserved.
Operating condi-
tions:
10 - 40 °C / 50 - 104 °F
15-90 % relative maximum humidity
Storage conditions: -20 - +55 °C / -4 - +131 °F
15-90 % relative maximum humidity
Weight: 277 g (including batteries)
Dimensions: 131 x 90 x 60.5 mm
Cuff size: from 17 - 52 cm according to the cuff
sizes (see «Selecting the correct cuff»)
Measuring proce-
dure:
oscillometric, corresponding to Korotkoff
method: Phase I systolic, Phase V
diastolic
Measurement range: 20 - 280 mmHg – blood pressure
40-199 beats per minute – pulse
Cuff pressure display
range:
0 - 299 mmHg
Resolution: 1 mmHg
Static accuracy: within ± 3 mmHg
Pulse accuracy: ± 5 % of the readout value
Voltage source: 4 x 1.5 V alkaline batteries; size AA
Mains adapter DC 6V, 600 mA
(optional)
Battery lifetime: approx. 920 measurements
(using new batteries)
IP Class: IP 20
Reference to
standards:
EN 1060-1 /-3 /-4; IEC 60601-1;
IEC 60601-1-2 (EMC); IEC 60601-1-11
Expected service life: Device: 5 years or 10000 measurements,
whichever comes first
Accessories: 2 years or 5000 measure-
ments, whichever comes first

Table of Contents

Other manuals for Microlife BP B2 Basic

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Microlife BP B2 Basic and is the answer not in the manual?

Microlife BP B2 Basic Specifications

General IconGeneral
TypeAutomatic
Cuff size22 - 42 cm
Control typeButtons
Product colorWhite
Number of users1 user(s)
Measuring methodOscillometric
Memory registers30
Pulse rate range40 - 200
Speaking functionNo
Placement supportedUpper arm
Units of measurementmmHg
Mean arterial pressureYes
Display typeLCD
Battery typeAA
Battery voltage1.5 V
Battery technologyAlkaline
Battery life (CIPA standard)920 shots
Number of batteries supported4
Quantity per pack1 pc(s)
Pressure accuracy1 mmHg
Pressure measurement range20 - 280 mmHg
Weight and Dimensions IconWeight and Dimensions
Depth90 mm
Width131 mm
Height60.5 mm
Weight277 g