16
Location 168 Area B Account Number.
If the panel has been partitioned, enter the Area B account number here. [Z8020C only]
Location 172 Auto Arming Time.
Enter the time of day for the panel to auto arm. The time must be entered in 24Hour format, example: 2030 is 8.30pm
or 0750 is 7.50am. If an invalid 24 hour time is entered the auto arm function is disabled. Panels are shipped with the
factory default 9999 [disabled]. Refer also Loc. 412 Led 4, also Loc. 347.
Location 176 Up/Download Password.
Enter 4 digits. This is the code that MicroCom will check to ensure that the downloading computer is authorised to
access the panel. The remote computer must have the same 4 digit code programmed to gain access.
Location 180 Test Signal Time.
Enter the time that the first test report will be sent to the central station. Subsequent test reports will be sent 24 hours
later. The time is entered in 24 Hour format [see Loc. 172]. If an invalid time is entered this function is disabled. A
test interval may also be programmed at Loc. 335 (Default = 24 hours)
Locations 184 254 Event Reporting Codes [Contact ID]
These locations are used for Contact ID reporting codes. If the panel is to communicate in Contact ID format these
locations are default pre-programmed. The panel reports standard Contact ID messages. If a non-standard message
is required, the second two digits of the 3 digit message may be entered at any of these locations. Erasing the data
at any location will disable that particular report in all formats. If the panel is to report only zone alarm and restore
data, opens and closes, then locations 200, 206 and 210 250 should all be erased using the 1 + 3 erase keys.
Once erased these functions will not report in any format.
Contact ID reporting codes
Event
Contact-ID code
Enter code
Medical alarm
100
00
Fire alarm
110
10
Smoke alarm
111
11
Heat
114
14
Fire call-station
115
15
Panic alarm
120
20
Duress
121
21
Silent panic
122
22
Burglary zone
130
30
Perimeter zone
131
31
Interior zone
132
32
24-hour alarm
133
33
Tamper
137
37
24-hour non-burglary
150
50
24-hour refrigeration
152
52
Water leak
154
54
AC power loss
301
01
Communications failure
354
54
Open/close
401
01
Zone bypass
570
70
Manual test
601
01
Periodic test
602
02
Locations 256 270 Zone Reporting Data [ Non Contact ID ]
For all other central station formats [except Contact ID] enter 2 digits at these locations. The central station normally
specifies the data entered. A usual format is 21 for zone 1, 22 for zone 2, …etc…where the 2 is the alarm code and
the second digit represents the zone activated.
Locations 272 314 Non Alarm Reports [ Non Contact ID ]
Enter 2 digits for each report. It is only necessary to enter digits for the reports that have NOT been disabled in
locations 184 to 254. If a report location is left blank and it has NOT been disabled in Loc‟s. 184 to 254 it will report
as 00. The central station always specifies the two digit codes for each of these reports.

Other manuals for Micron Scorpion Z4120C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Micron Scorpion Z4120C and is the answer not in the manual?

Micron Scorpion Z4120C Specifications

General IconGeneral
BrandMicron
ModelScorpion Z4120C
CategoryNetwork Router
LanguageEnglish

Related product manuals