Location 418 Zones to Activate the Aux. Output 2
The same rules apply here as at Loc. 414 except that the Aux. 2 output will be enabled.
Location 420 System Events to Activate the Siren Output
Led 1 On: NiteWatch panic.
Led 2 On: Two key panic.
Led 3 On: Fire panic.
Led 4 On: Siren output fault. (use in Loc‟s 422 & 424)
Led 5 On: Communications failure.
Led 6 On: Phone line failure.
Location 422 System Events to Activate Aux. Output 1
Same options as at Loc. 420.
Location 424 System Events to Activate Aux. Output 2
Same options as at Loc. 420.
Location 426 Output Options
Led 1 On: Siren output normally pulled low [-ve]
Off: Siren output normally floating [open circuit]
Led 2 On: Aux. output 1 normally pulled low [-ve]
Off: Aux. output 1 normally floating [open circuit]
Led 3 On: Aux. output 2 normally pulled low [-ve]
Off: Aux. output 2 normally floating [open circuit]
Led 4 On: Siren output produces siren wail for horn speakers.
Off: Siren output switches low/open for siren speakers with built-in driver [see led 1]
Led 5 On: Aux. output: 1. 7 # command resets smoke detectors [momentary 5 sec]
Off: No smoke reset.
Led 6 On: Aux. output: 2. 7 # command resets smoke detectors [momentary 5 sec]
Off: No smoke reset.
User Code Options - Programming
Location 428 User Code 1 Options
Select the functions for this user code. By default, if no options are selected the user code will arm/disarm the panel
and all other functions are disabled.
Led 1 On: User code controls Area B [Z8020C only].
Led 2 On: User code is Master Code [can program other user codes].
Led 3 On: User code is an Arm Only code, cannot disarm.
Led 4 On: User code can Exclude Zones at arming.
Led 5 On: User code activity does NOT send reports.
Led 6 On: User code can arm/disarm remotely from touch tone phone.
Locations 430 474 User Codes 2 to 24 Options
Select options from the list at Loc. 428.
Location 456 User Code 15 Options
User code 15 is reserved as a „disarm all areas‟ code for a partitioned Z8020C (this code can not arm any area or
perform any other function) and as a night-lock code for a Z4120C and Z6020C systems. If the Z4120C or Z6020C is
armed with user code 15, only this user code can disarm the system.
Led 5 On: User code activity does NOT send reports.
Led 6 On: User code can disarm both areas remotely from touch tone phone.
Location 476 Quick Arm Reports
Led 5 On: Does not report.
Off: Reports Quick Arm [1 #] as User 25.
Location 478 Night Arm or Instant Arm Reports
Led 5 On: Does not report.
Off: Reports Night and Instant arming [9 1 #] as User 26.

Other manuals for Micron Scorpion Z4120C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Micron Scorpion Z4120C and is the answer not in the manual?

Micron Scorpion Z4120C Specifications

General IconGeneral
BrandMicron
ModelScorpion Z4120C
CategoryNetwork Router
LanguageEnglish

Related product manuals