Call Remote Computer. [Toll Saver]
Enter 9 9 # n n n n n n n, where „ n n n n n n n „ is the phone number for a remote computer. The panel waits 2.5
seconds after 9 9 # for the first digit to be entered and 2.5 seconds after each successive digit. If no further digits are
entered within 2.5 seconds the keypad beeps twice and the panel then waits 30 seconds for a remote computer
modem tone. If connection is not successful the panel disconnects from the line.
Two Key Panic.
Two key panic audible alarm is selected at Loc. 420, led 2 and reporting is selected at Loc.216. Press Star + Hash
[* + #] together to activate this function. Reset the panel by entering any valid user code.
Fire Panic.
Enable audible at Loc. 420, led 3. Enable reports at Loc. 220. Press 1 + 3 together to activate. Reset the panel
with a valid user code.
Medical Panic.
Press 4 + 6 together to activate. Reports only (no audible). Reset the panel with a valid user code.
Clone Memory from / to Prom Socket.
Fit the clone chip into the socket. Enter the master programming code n n n n then # then 1 + 3. The data
programmed in the clone chip is copied into the panel memory. To copy data from the panel to the clone socket,
enter the master programming code n n n n then # then 4 + 6. [note: The master programming code and
communicator account number are not copied ].
Arming and Disarming the Panel.
Enter a valid user code followed by the Hash [#] key.
Sending Duress after Disarming.
To transmit a duress code while disarming, enter a valid user code then press the # key and keep held down until a
second beep is heard (about 1 second) then release. An „opening‟ and „duress‟ will be sent to the monitoring station.
Opening After an Alarm.
If the alarm control has been programmed NOT to report by user [Loc 428 – 482], and an alarm condition occurs, on
disarming the system the control will send an opening report to the monitoring station.
Arming the Panel and Excluding a Zone(s).
Enter a valid user code then Star [all zone led‟s light] then zone number(s) to exclude [leds off] then Hash.
Example: n n n n then * then 236 then #. In this example the panel will arm with zones 2,3 and 6 excluded.
Swinger Shutdown.
The swinger shut down count is programmable at Loc. 359 and may be set in the range 1 to 7. When the programmed
number of activations has occurred within any one arming cycle the zone is disabled and can not generate further
alarms until the panel is disarmed and re-armed. This rule applies to all zones including zones programmed as night
or 24 hour zones.
Adding, Changing or Deleting a User Code.
Enter a master user code then 1 + 3 then a new user code then # then the user number [1 to 15]. To delete a
user code follow exactly the same procedure as above but omit the „new user code‟. Finish with #.
Temporary User Codes.
User codes 8 and 9 may be programmed by the end user as „temp‟ user codes by making the first digit a 15 (Star + 5).
Example: user code 8 programmed as 15 1 2 3. Entering the last 3 digits of the temp code will arm/disarm the panel.
The panel discards temp codes at midnight. The panel clock MUST be set.
Adjusting the Battery Charging Voltage.
The battery charging voltage is factory pre-set. If it becomes necessary to adjust the voltage proceed as follows:
Enter N N N N (programming code) then # then [star + hash]. Now press 1 to step down the charging voltage or
3 to step up the voltage. Press # to save the voltage setting or * (star) to abort. Warning: Do not attempt to adjust
the charging voltage if the battery is partially discharged or if the battery is old or if the Aux. supply voltage is heavily
loaded. The battery charge voltage (with a fully charged battery connected) should NEVER exceed 13.80 volts.
Emergency Access to Program Mode.
If the master programming code is lost and the installer has not disabled this function at Loc.410, led 3 then proceed
as follows: Disconnect all power from the panel. Hold down the 1 + 3 keys while power is re-connected to the panel
(two beeps) then press the # key within 6 seconds. The panel will jump directly to „Program‟ mode. If this function
has been disabled at Loc. 410 the panel can not be accessed and must be returned to a Micron master distributor.