23
Technical Specifications
AC Input …………………16VAC from transformer (do NOT exceed)
Accessory Power ……….13.8VDC. 500mA total drain.
Aux. Output 1…………… Max. 250mA Sink output.
Aux. Output 2…………… Max. 250mA Sink output.
Siren Output……………...Max. 1.5 Amps DC to non inductive load or:
2 x Siren speakers with built in driver @ 350mA per siren.
2 x 4ohm reflex horn speakers when siren wail output selected.
Battery Capacity…..……..Max 7.2 A/H
Battery Fuse…..………….3 Amp fast blow.
Outputs: Aux. outputs 1 and 2 are open collector sink outputs. When connecting a load to these outputs they should
be thought of as switches that close to Ve when activated. Therefore connect loads between +Ve and the
output. Do not exceed the rating stated above or permanent damage will result to the output transistors.
EOL Resistors: All zones are balanced line with standard 4K7 (+- 5%) value EOL resistors.
Keyswitch Arming: Arming and disarming is achieved by momentarily shorting and restoring a keyswitch zone.
TELECOM WAIVER
The grant of a Telepermit for any item of terminal equipment indicates only that Telecom has accepted that the item
complies with the minimum conditions for connection to its network. It indicates no endorsement of the product by
Telecom, not does it provide any sort of warranty. Above all, it provides no assurance that any item will work correctly
in all respects with another item of Telepermitted equipment of a different make or model, nor does it imply that any
product is compatible with all of Telecom‟s network services.
This equipment is set up to carry out test calls at pre-determined times. Such test calls will interrupt any other calls
that may be set up on the line at the same time. The timing set for such test calls should be discussed with the
installer. The timing set for test calls from this equipment may be subject to „drift‟. If this proves to be inconvenient
and your calls are interrupted, then the problem of timing should be discussed with the equipment installer. The matter
should NOT be reported as a fault to Telecom Faults Service.
Recommended Method of Connection to the Telecom Network
1 Fit an RJ31X Single Line Junction Box alongside the existing Telecom Master Socket.
2 Locate the telephone line wires, which are connected to terminals 2 and 5 in the Telecom Master Socket and
make some form of identifying mark on the wire connected to terminal 2.
3 Disconnect the 2 telephone line wires from terminals 2 (marked wire) and 5 in the Telecom Master Socket and
connect them to terminals 4 (marked wire) and 5 in the RJ31X Junction Box.
4 Add a connecting wire from terminal 1 RJ31X Junction Box to terminal 5 in the Telecom Master Socket.
5 Add a connecting wire from terminal 8 in the RJ31X Junction Box to terminal 5 in the Telecom Master Socket.
6 Check that all other wires within the Telecom Master Socket are connected securely, especially if these have
been disturbed during the re-wiring.
7 Check that all existing telephone equipment still functions correctly.
8 Plug the line cord from the Security System into the socket on the RJ31X Junction Box.
9 Check again that all existing telephone equipment still functions correctly.
10 Check that the Security System equipment functions correctly.
This equipment must not be programmed for decadic (pulse) dialing because its characteristics are incompatible with
the telephone exchanges in New Zealand. DTMF (tone) dialing is considerably faster and is fully compatible.
Connection to Mains Earth
For protection against hazards from over voltages on the telecommunications network it is important that the green
earth wire from the printed circuit board is connected to a secure mains earthing point.

Other manuals for Micron Scorpion Z4120C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Micron Scorpion Z4120C and is the answer not in the manual?

Micron Scorpion Z4120C Specifications

General IconGeneral
BrandMicron
ModelScorpion Z4120C
CategoryNetwork Router
LanguageEnglish

Related product manuals