Location 400 Pre-alert Zones Select
Select zones that will activate the keypad beeper during entry. Zones selected must also be selected at Locs.
374 or 376 and 390, 392.
Location 402 Chime Zones Select
Select zones to activate the keypad beeper when the panel is unset and chime mode is turned on.
System Settings - Programming
Location 404 Output Mimics Keypad Beeper
Outputs selected here will mimic the keypad beeper eg. exit / entry beeps, door chime, error beeps, etc. Key press
beeps are NOT mimicked.
Led 1 On: Siren Output
Led 2 On: Aux. Output 1.
Led 3 On: Aux. Output 2.
Location 406 Output Mimics Panel Armed / Disarmed Status Area A.
Outputs selected here mimic the panel armed / disarmed status. Outputs change as soon as a valid user code is
entered, not at the expiry of the exit delay.
Led 1 On: Siren Output
Led 2 On: Aux. Output 1.
Led 3 On: Aux. Output 2.
Location 408 Output Mimics Panel Armed / Disarmed Status Area B.
Outputs selected here mimic the panel armed / disarmed status. Outputs change as soon as a valid user code is
entered, not at the expiry of the exit delay.
Led 1 On: Siren Output
Led 2 On: Aux. Output 1.
Led 3 On: Aux. Output 2.
Location 410 Miscellaneous System Settings
Led 1 On: Zone leds latch on when panel is unset and the zone is tripped
Off: Zone leds toggle on and off when panel is unset and zone is tripped.
Led 2 On: Quick arming command enabled [ 1 # area A or 2 # area B ]
Off: Quick arm disabled.
Led 3 On: 1+3 keys at power-up jump to programming mode [emergency access].
Off: 1+3 command at power-up disabled.
Led 4 On: 60Hz Mains power.
Off: 50Hz Mains power.
Led 5 On: Answer phone defeat enabled [double call].
Off: Answer phone defeat disabled.
Led 6 On: User access to „Follow Me‟ (home dial) mode enabled. (see page 21)
Off: „Follow me‟ mode disabled
Location 412 More Miscellaneous System Settings
Led 1 On: Zone restore reports are disabled.
Led 2 Reserved
Led 3 On: Auto arming will night / instant arm.
Off: Auto arming will away arm.
Led 4 On: Forced arming enabled.
Led 5 On: Decadic dial make break ratio 70/30
Off: Decadic dial make break ratio 60/40
Led 6 On: Default dialing is decadic (pulse)
Off: Default dialing is DTMF (touch-tone)
Siren and Aux.1 & 2 Outputs - Programming
Location 414 Zones to Activate Siren Output
Select the zones that will activate the siren output. If a zone is to be a „silent alarm‟ zone do not turn on the led for that
zone. Zones NOT selected here will still report.
Location 416 Zones to Activate the Aux. Output 1
The same rules apply here as at Loc. 414 except that the Aux. 1 output will be enabled.