EasyManua.ls Logo

Microscan Visionscape FrontRunner - Simulating Triggers

Microscan Visionscape FrontRunner
152 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 FrontRunner™
2-22 Visionscape FrontRunner™ User’s Manual v4.1.3, April 2012
Simulating Triggers
Note: For more information about triggers with the VS-1 Smart Camera,
see the Advanced Triggering Techniques section in Chapter 1 of the
Visionscape
®
Tools Reference.
FrontRunner™ allows you to simulate a trigger in a Job for diagnostic
purposes.
Use the following procedure to simulate a trigger:
1. Create a new Job or open an existing Job.
2. Click Editor to display the Editor window.
3. In the left pane, select Acquire.
Note: You may have to click the Acquire tab.
4. In the right pane, click to the right of the Trigger property.
5. From the leftmost pull-down menu, select Virtual Point.
6. To the right of Virtual Point, select a number. For example, 0001.
7. Close the Editor window.
8. Click the I/O button.
FrontRunner™ displays the I/O Display window, as shown in
Figure 2–11.

Related product manuals