Chapter 2 FrontRunner™
2-22 Visionscape FrontRunner™ User’s Manual v4.1.3, April 2012
Simulating Triggers
Note: For more information about triggers with the VS-1 Smart Camera,
see the Advanced Triggering Techniques section in Chapter 1 of the
Visionscape
®
Tools Reference.
FrontRunner™ allows you to simulate a trigger in a Job for diagnostic
purposes.
Use the following procedure to simulate a trigger:
1. Create a new Job or open an existing Job.
2. Click Editor to display the Editor window.
3. In the left pane, select Acquire.
Note: You may have to click the Acquire tab.
4. In the right pane, click to the right of the Trigger property.
5. From the leftmost pull-down menu, select Virtual Point.
6. To the right of Virtual Point, select a number. For example, 0001.
7. Close the Editor window.
8. Click the I/O button.
FrontRunner™ displays the I/O Display window, as shown in
Figure 2–11.