EasyManua.ls Logo

Microscan Visionscape FrontRunner - Examining I;O Transitions (Digital Soft Scope)

Microscan Visionscape FrontRunner
152 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 FrontRunner™
2-24 Visionscape FrontRunner™ User’s Manual v4.1.3, April 2012
13. In the FrontRunner™ window, click Settings.
FrontRunner™ displays the Settings dialog box.
14. In the Settings dialog box, click to select Use I/O During Tryout and
Use Triggers During Tryout.
15. Close the Settings dialog box.
16. Download the Job to the Smart Camera.
17. Start the Job.
18. In the I/O display window, click Start Triggers.
Important Note
When using Virtual I/O points to generate triggers at regular interval, as
programmed in the Visionscape
®
IO Display or the FrontRunner RunView
IO bar the accuracy of the timing between triggers will depend on the
Operating System the avp runs on and also on the number of Virtual I/O
points programmed to be triggers. The following information provide
guidelines based on Device/OS configurations:
GigE Cameras and Software Systems — Triggers generated by the
avp, IO display and FrontRunner IO bar.
Windows XP — Accuracy +/- 5 msec typical, trigger to trigger
time increases as more triggers are generated.
Windows 2000 — Accuracy +/- 25 msec typical, trigger to trigger
time increases as more triggers are generated.
Note: The values above are typical and may vary from PC to PC.
Accuracy should be measured/tested first for the particular avp for the
particular PC.
When greater accuracy than the Device allows is required, physical
triggers should be used instead.
Examining I/O Transitions (Digital Soft Scope)
Digital Soft Scope examines I/O transitions recorded in a DSS file: