Factory Default Settings
Associations
The following default associations are configured:
IP Address Role Poll Interval Burst MD5 Key
Hardware ClockServer
69.25.96.11 ServerDefault iburst None
69.25.96.12 ServerDefault iburst None
69.25.96.14 ServerDefault iburst None
MD5 Keys
MD5 Keys - Default Settings
None defined
NTP Override Behaviour
NTP Override Behaviour - Default Settings
Configured to Follow Standard NTP Rules
TIMING
TimeZone
Time Zone - Default Settings
Local Time Zone is set to UTC
HardwareClockConfiguration
Hardware Clock Configuration - Default Settings
All installed Clock Sources are Enabled (e.g., on an S250, the installed references are: GPS,
IRIG-B, 1PPS, and 10MHz).
Forced Timing Source is set to Auto
Ignore UTC Corrections from GPS Reference (not present on S250i) Not Selected
Holdover
Holdover - Default Settings
Holdover Configuration Time Error Limit is set to 1 (one) millisecond