Frequency: 1575.42 MHz (L1 signal)
Code: Coarse Acquisition (C/A) code
Tracking: Up to 12 satellites. All 32 PRN's.
Position Accur-
acy:
Typically <10m w. four satellites. Available from web interface.
1PPS Accur-
acy:
50 nS RMS, 150 nS Peak to UTC-USNO
Time standard: UTC
Signal strength:
1 sat -166 dBW to acquire, and -171 dBW to track.
Cabling options:
n
150 ft. of Belden 9104 (RG-59 type)
n 300 ft. with inline amplifier
n Compatible with down/up converter
Also see:
n GPS Antenna
n GPS Cable Configurations/Options (see "Distance Between Antenna and Receiver"
on page 105)
Safety Standards
Meets the following safety standards:
n 73/23 EEC CE Low Voltage Safety Directive
n EN 60950-1:2001
n UL 60950-1:2003
n CSA 22.2 60950-1:2003
n IEC 60950-1:2001
n AS/NZ 60950-1:2003
n PSE Japan
EMC Standards
Meets the following EMC standards:
n FCC Part 15 Subpart B
n 2004/108/ECCE EMC Directive
n EN55022 (1998) EMC Emissions for ITE, Class A
n EN55024 (1998) EMC Immunity for ITE
n EN61000-3-2 (2000)Harmonic Current Emissions
n EN61000-3-3 (1995)Voltage Fluctuations and Flicker Emissions
n VCCI: April 2000Japan EMC Standard
n ICES-003Canada EMC Standard
n AS/NZS CISPR 22:2002Australia/New Zealand EMC Standard