MICROSENS 8 Port Gigabit Ethernet Switch User’s Manual
117
Function name:
802.1X State Setting
Function description:
This function is used to configure the global parameters for RADIUS authentication in
802.1X port security application.
Parameter description:
Radius Server:
RADIUS server IP address for authentication.
Default: 192.168.1.1
Port Number:
The port number to communicate with RADIUS server for the authentication service.
The valid value ranges 1-65535.
Default port number is 1812.
Secret Key:
The secret key between authentication server and authenticator. It is a string with the
length 1 – 31 characters. The character string may contain upper case, lower case and
0-9. It is character sense. It is not allowed for putting a blank between any two
characters.
Default: Radius
Fig. 3-55