调高器说明书
and the current height value.
3. Parameter editing mode: to display the parameter names being
edited and the corresponding parameter values.
7.3 Description of Display
Manual
operation mode: The first digit indicates the det ection
mode;
the second one indicates the operation state and the last 3 digits
indicate the set
value of height.
The first digit: C: capacitance detection mode, U: arc voltage
detection
mode.
The second digit: no operation, flashing between and ; t he former
st ands for manual ascending and the latter stands for manual descending:
The last 3
digits: in capacitance mode, it is a decima l in mm; in arc voltage
mode, it is an integer in V.
Aut omatic operation mode: The first digit indicates the detection mode
(t he same as shown above); the second one indicates the operation
state and the last 3 digits indicate the set value
of height (the same as
shown above). The second digit is particularly described as follo
ws:
When is fixed, it indicates t he cut ting t orch is moving up
at high speed.
When is flashing, it indicates the cutting torch is moving
up at the a regulated speed.
When is fixed, it indicates the cutting torch is moving down
at high speed.
When is flashing, it indicates the cutting torch is moving
down at a regulated speed.
When is flashing, it indicates the cutting torch arrives t he
expected place.
36
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fine
print.com.cn