Functions
5.2.2 Date settings
No
Function
1
Tap the input box to enter a name for the schedule. Maximum length is 80 English characters (40 Chinese
characters). Note that system is unable to save the name if it contains the following symbols:
[`~!#$^&*()=|{}':;,\.<>/…?~!¥ () ——【】 ‘’ “”、?;《》 ].
2
Tap in the white space to select the corresponding starting and End dates for the schedule.
3
Check the blue icon on the left next to Holiday to activate the holiday exception function which is to not carry out
all the plans in the schedule during the holiday period. The icons that are checked are active .
4
Daily and weekday two options are available to quickly select.
5
Manual option for weekly plan. Tap the day to activate or deactivate it. Blue indicates active status, while white
indicates inactive status. Using this, the schedule will be implemented on that particular day only.
6
You can add a custom date to the schedule as an individual date. Tap the "+" sign to add a date each time and you
may add up to 5 dates. Tap once to select and add the date. Tap "x" at the top left corner to delete this date. Tap the
date in other areas to deselect it
Note:* The schedule will not be implemented during the holidays unless the holiday exception is selected; The schedule in the custom dates outside the holiday
is implemented, even if the date falls outside the period of validity (expiration date) or is part of a weekly plan; The schedule for the remaining dates must be
within the period of validity (before expiration date), and must satisfy the weekly plan.
5.2.3 Add Schedule Command
Tap on , to create a table and you will get the dialog box to add the timings. There are four
different command types that you can add and these are FAPU, HRV, Auto and No Auto. Once the table is ready, you can
use to create a schedule command.
1. For Fresh Air Processing Unit (FAPU), you can choose from 3 modes: cool, heat and fan. In the Fan mode, you cannot
change the set point temperature. The range of the set point in cool and heat modes is 17-30 degrees Celsius. The fan
speed for cool and heat with fan is Speed 7 + Auto.