1) Remove the air duct components in freezing
chamber.
2) Disconnect all connectors.
3) Remove the welding on inlet and outlet tubes.
4) Remove two screws which are used to fix the
evaporator and remove the evaporator.
Defrost heater with defrost sensor and fuse, it can be
replaced separately.
1) Cut off wiring terminal
2) Cut off the band which fixes the sensor
3) Cut off the band which fixes the fuse
4) Separate the sensor and the evaporator
Take off the defrost heater from the supporting plate of
evaporator