36
Chapter 8: Jump Start (System Test)
The EXP’s Jump Start routine assists a discharged battery so that you can complete the Starter Test
portion of the System Test.
1. When the JUMP START instruction screen is displayed, disconnect the analyzer’s clamps
from the battery posts.
2. Make sure the charger’s power cord is disconnected and the power switch in the OFF
position.
3. Connect the charger’s clamps to the battery posts: red lead to the positive (+) terminal,
black lead to the negative () terminal.
4. Reconnect the analyzers clamps to the battery posts. Rock them back and forth so they
make good contact.
5. Turn on the booster pack or charger.
6. The EXP will monitor the level of the battery’s voltage for a maximum of 30 seconds.
7. When the time counts down to 0 seconds or the battery voltage is sufficient, the EXP will
instruct you to start the engine.
8. The EXP will display the Starter Test results (See Table 2).
9. Disconnect the booster pack or battery charger.
The EXP will continue with the alternator test.
Chapter 8: Jump Start (System Test)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midtronics intellect EXP-1000 and is the answer not in the manual?

Midtronics intellect EXP-1000 Specifications

General IconGeneral
BrandMidtronics
Modelintellect EXP-1000
CategoryTest Equipment
LanguageEnglish

Related product manuals