Technical Information
G600 & G800 Electronic Dishwashers
With the Float Switch actuated; power that is normally distributed
throughout the appliance is re-directed to the Drain Pump. The Drain
Pump will continuously operate when the unit is turned on and the door
is closed. Normal operation and Program Selection is not possible
during this time.
Warning!
If the WPS is replaced, always ensure the correct flow restrictor is
installed
The WaterProof system only operates with the door closed and the
dishwasher switched on.
To ensure optimal protection, the water connection should be at
least 20 cm higher than the floor on which the dishwasher is
standing.
The connection hose must be routed so that no point is higher than
the connection housing.
For further details, refer to the model specific Operating and
Installation Manual.