Problem solving guide
135
Spray arm monitoring/wash pressure
Problem Cause and remedy
Spray arm monitoring - upper
spray arm: Spray arm blocked
or excessive foaming
or
Spray arm monitoring - lower
spray arm: Spray arm blocked
or excessive foaming
or
Spray arm monitoring - mobile
unit spray arm 1 - : spray arm
blocked or excessive foaming
The set spin speed has not been reached.
– Load items are obstructing the machine or basket spray
arms.
Arrange the load items so that the spray arms can turn
easily and start the programme again.
– The relevant spray arm is blocked.
Clean the spray arm.
Check whether the filters in the wash cabinet are clean
and correctly inserted.
Start the programme again.
– Wash pressure is too low due to a heavy build-up of
foam.
Follow the instructions regarding foam build-up in
“Chemical processes and technology”.
Start the Rinsing programme in order to clean the wash
cabinet.
Then reprocess the load items again.
Wash pressure exceeds tol-
erance
The wash pressure differs from the reference value.
Possible causes of fluctuations in the wash pressure
include:
-Defective water connections,
-Open adapters,
-Foam build-up.
Identify and resolve the cause of this.
The programme is not interrupted. Nevertheless, you
must reprocess the load.
Wash pressure fluctuating too
much
A programme was interrupted because of severe
fluctuations in the wash pressure.
Possible causes of fluctuations in the wash pressure
include:
-Defective water connections,
-Open adapters,
-Foam build-up.
Identify and resolve the cause of this.
Reprocess the load again.

Table of Contents