Electrical connection
,
This installation should be
performed by an experienced and
qualified technician, in accordance
with local codes and regulations.
The dryer comes with a power cord
without a plug.
The machine is supplied as standard
for connection to a 208 V, 60 Hz,
3 x 30 A, 3-phase electrical supply.
For extra safety it is advisable to install
a residual current device (RCD) with a
trip current of 30 mA.
If the machine is hard wired, three 30 A
circuit breakers must be provided
on-site. Switches with a contact gap of
more than 1/8" (3 mm) are valid as
separators. All components have to
bear CSA or UL approval.
The machine must only be connected
to the voltage and frequency shown on
the data plate.
,
To convert the machine to
another electrical connection,
please read the conversion manual
on the wiring diagram inside the
dryer. The conversion must be
performed by a Miele Service
Technician.
,
Do not install devices to
automatically turn the dryer off
e.g. clock timer.