21
Bit2~Bit0:
000-disable
001-below
010-above
011-within
below or above
Bit5~Bit3:
001-Standard Mode
010-Bin Mode
Bit6=0
Bit7:
0 - disable threshold dismiss report
1 - enable threshold dismiss report
70 (Set Height Threshold in
Parking Lot Mode)
2 Bytes, unit: mm
77 (Set Installation Height)
2 Bytes, unit: mm
Example:
1. Set reporting interval as 20 minutes.
ff03b004
Channel
Type
Value
ff
03 (Set Reporting Interval)
b0 04 => 04 b0 = 1200s = 20 minutes
2. Reboot the device.
ff10ff
Channel
Type
Value
ff
10 (Reboot)
ff (Reserved)
3. Set the device as standard mode.
ff7100
Channel
Type
Value
ff
71 (Set Device Mode)
00 = Standard Mode
4. Enable Tilt & Distance Switch feature.
ff3e01
Channel
Type
Value
ff
3e (Set Tilt & Distance Switch)
01 = Enable