4. When the distance is below 20cm or above 80cm, the sensor will send threshold alarm.
ff3e 8c c800 2003 0000 0000
CTRL: cc=10 001 100
100=below or above
001=standard mode
10=enable threshold dismiss
report
Min: c8 00 => 00 c8 = 200 mm
= 20 cm
Max: 2003 => 03 20 = 800 mm
= 80cm
5. Set duration of motion to 50s and duration of stationary to 180s.
58(Duration of Motion and
Stationary)
Duration of motion: 32=50s
Duration of stationary: b4 00 00 00=00
00 00 b4=180s
-END-