SECTION 7 MAINTENANCE AND TROUBLESHOOTING
7-1. Routine Maintenance
Y Disconnect power before maintaining.
. Maintain more often during severe conditions.
3 Months
Replace
unreadable
labels.
Clean and tighten
weld terminals.
Replace Damaged
Gas Hose
3 Months
Repair Or Replace
Cracked Cables
And Cords
6 Months
Blow out inside. During
heavy service clean
monthly.
Y Do not remove case when
blowing out inside of unit
(see Section 7-2) .
7-2. Blowing Out Inside Of Unit
Y Do not remove case when
blowing out inside of unit.
To blow out unit, direct airflow
through front and back louvers as
shown.
803 428-A

Table of Contents

Questions and Answers:

Miller DYNASTY 200 DX Specifications

General IconGeneral
Welding Amperage Range1-200 A
Output Current Range1-200 A
Pulse Frequency0.5 - 500 Hz
AC Frequency20-250 Hz
ProcessesTIG (GTAW), Stick (SMAW)
Output Power200 A at 26 V, 40% duty cycle
Input Power120 V, 208 V, 220/230/240 V, 460 V, 575 V, 1- or 3-Phase