Congratulations!
Thank you for buying a Milli-Q
®
water purication system.
The Milli-Q
®
IX 7003/7005/7010/7015 water purication system produces pure water from a tap
water source. Installation of this product should be performed by a qualied service representative
with access to installation documentation.
This user manual is a guide to be followed during the normal operation and maintenance of a
Milli-Q
®
IX 7003/7005/7010/7015 water purication system. It is highly recommended to fully
read this manual and comprehend its contents before using the water purication system.
System identication
System Catalogue number
Production
ow rate
Voltage Frequency
Milli-Q
®
IX 7003 ZIX7003T0 3 L.h
-1
100-240 V 50-60 Hz
Milli-Q
®
IX 7005 ZIX7005T0 5 L.h
-1
100-240 V 50-60 Hz
Milli-Q
®
IX 7010 ZIX7010T0 10 L.h
-1
100-240 V 50-60 Hz
Milli-Q
®
IX 7015 ZIX7015T0 15 L.h
-1
100-240 V 50-60 Hz
Manufacturing site:
Millipore SAS, 67120 Molsheim, France
For more information on your Milli-Q
®
system, please call your local representative or visit
our website www.emdmillipore.com (North America) or www.merckmillipore.com (Rest of the
World).
Intended use
The Milli-Q
®
IX 7003/7005/7010/7015 system is intended to produce pure (type 2) water from
a tap water source primarily for use in research and quality control in a variety of laboratories
worldwide.
The product is designed to produce pure water with specic characteristics (refer to the
requirements and specications section) when it leaves the E-POD
®
unit, provided that it is fed
with water quality within specications and properly maintained as required by the supplier.
Merck KGaA, Darmstadt, Germany does not warrant the product for any specic application. It is up to
the user to determine if the quality of the water produced by the product matches their expectations,
ts with norms/legal requirements and to bear responsibility resulting from the usage of the water.
The product is not intended to produce: water for injection, water for dialysis, sterile water for
irrigation or injection, bacteriostatic water for injection, sterile puried water in containers, and
sterile water for injection in container or ingestion. The product is not intended to be used in
explosive environments according to ATEX Directive – equipment & protective systems intended
for use in potentially explosive atmospheres. In addition the product is not intended as a Medical
Device, including In-Vitro Devices.