The processed echo display ( P-79 ) can be made to show not only the processed
echo profile, but also the:
echo marker
window
TVT curve or auxiliary window
Typical scope settings for viewing the processed echo are:
gain - 1 v / d
sweep - 1 msec / div
The following are restricted to transmission in air at 20 °C.
to obtain a time measurement of the processed echo, the sweep time must
be multiplied by a factor of 10
to obtain a time measurement of the transmit or receive signal, use the
actual sweep setting
to obtain a distance measurement of either of the above types of echoes,
divide the respective time measurement by 1.8 msec / ft or 5.9 msec / m
Typical Scope Display
Scope Display LCD display ( P-79 )
Window u
Marker n
Curve - TVT c
Profile P
TVT curve
window
( near blanking )
echo profile
echo marker
( far end blanking )