Pellerin Milnor Corporation 33
washer-extractor is running and selects the chemical injection program corresponding to the wash
formula.
Display or Action Explanation
CHEM 1 INJ TIME: SSS
FORMULA 01 030
Typical display with formula number field selected for change.
Scrolls the formula number up or down.
Accepts the selected formula number and moves the cursor to the
injection time field.
Accepts the current digit of the formula number and moves the
cursor back to the previous decision (Time to Drain).
Writes all data to memory and returns to the Program menu.
CHEM 1 INJ TIME: SSS
FORMULA 04 030
Typical display with the first digit of the time field for formula 4
selected.
Scrolls the selected digit up or down. The maximum value for any
signal is 255 seconds; the minimum value is 000 (no injection).
Accepts the current digit of the inject time and moves the cursor
forward to the next digit. When the third digit is selected, the cur-
sor advances to the formula number for the next formula.
Accepts the current digit of the inject time and moves the cursor
back to the previous digit. If the first digit of the inject time is se-
lected, the previous decision (Time to Drain) is displayed.
NOTE: All inject times return to the default value of 30 seconds any time the standard
formulas are restored to memory. The procedure for restoring standard formulas is de-
scribed below.
Accepts the current digit and saves all configure data.
***PLEASE WAIT***
Appears while the controller writes all configure data to memory.
PROGRAM 2 MENU
CONFIGURE
Indicates that all configure data was successfully written to mem-
ory. Select another program menu option to continue.
2.3.5 Restoring the Standard Formulas
BNCXUP13.C01 0000209293 A.5 D.3 A.3 1/2/20 1:35 PM Released
Programming mode 3 allows the owner/operator with access to a programming key to perform
either of these two actions:
1. Option 0 replaces all existing formulas with the factory default formulas for the selected in-
dustry configuration. This selection replaces formulas 1 through 10 with the standard industry
formulas and removes all data from formulas 11 through 30.
2. Option 1 replaces only formulas 1 through 10 with the standard industry formulas. This
leaves any user-programmed data in formulas 11 through 30 intact.
Programming

Table of Contents