Pellerin Milnor Corporation 57
page 53 ), the settings of other switch positions are only apparent from this display or by looking
at the processor board.
Display or Action Explanation
Enters the Manual menu from the Run mode.
MANUAL MENU
1 SOFTWARE DATE CODE
This is the first item of the Manual menu.
,
Scrolls down to the Test DIP Switch item.
MANUAL MENU
4 TEST DIP SWITCH
This is the Test DIP Switch item of the Manual menu.
Accesses the Test DIP Switch function and displays the DIP
switch setting.
052
This is an example of the DIP switch display. Referencing this
number in Table 10 shows that the sample machine is configured
for Restaurants Laundry, and that switch positions 5 and 6 are
enabled.
Terminates the Manual menu and returns controller to Run
mode.
Table 10. Interpretation of Test DIP Switch Display
Industry
Configuration
Standard Dis-
play Value
Value if Position
5 is ON
Value if Position
6 is ON
Value if Both Po-
sitions 5 and 6
are ON
Correctional 0 16 32 48
Hotel/Motel 1 17 33 49
Athletic 2 18 34 50
Healthcare 3 19 35 51
Restaurants 4 20 36 52
Commercial 5 21 37 53
Shirt Laundry
6 22 38 54
Offshore 7 23 39 55
4.2.6 Viewing Inputs and Outputs During Operation
BNCJHT06.R04 0000209622 A.5 A.7 B.2 4/28/20 3:07 PM Released
While the machine must be idle to actuate outputs, inputs and outputs can be viewed (but not
turned on or off) while the machine is operating.
Display or Action Explanation
23:04 F02S01 02:37
L=A1/D1 Hot Wash
This is a typical display while the machine is running a formula.
displays the inputs. A plus sign (+) indicates the input is
grounded, while a minus sign (–) indicates the input is not
grounded.
Testing and Troubleshooting