26
Pellerin Milnor Corporation
2.3.3.6.2 The Step Decisions
BNCJUP03.C13 0000191935 C.2 D.2 C.3 1/2/20 1:16 PM Released
A maximum of 30 formulas may be programmed, with a maximum combined total of 225 steps
in all formulas.
Display or Action Explanation
03 TMMQFFFHC LSCWSS*
This is a typical Type of Step decision display. The actual format
of the display varies according to the specific machine controller
and certain configure decisions.
01
0
End formula: The last step of each formula must be of type 0. This
step is automatically added as a last step if the previous step is
type 6 (final extract). The basket moves or stops as directed by the
How to End programming decision, described in 2.3.3.6.7: Con-
cluding Decisions, page 34 . A formula may be ended without a fi-
nal extract by setting the last step to type 0. If the last step before
the End Formula step is a type other than final extract, the con-
troller will ask “End Formula #xx?”.
Setting the first step of an existing formula to type 0 deletes the
formula, as described in 2.3.3.5: Delete an Existing Formula, page
24 .
1
One-way wash: Washing routine which may increase mechanical
action and reduce energy consumption to some degree. Use for
smaller pieces where tangling and “roping” is not a consideration.
The basket rotates clockwise at the programmed wash speed for
the duration of the step.
2
Two-way wash: Washing routine for items which tend to rope and
tangle unless reversed. The basket rotates clockwise for some pe-
riod of time, then pauses for a few seconds before rotating in the
opposite direction.
3
Soak wash: The cylinder does not turn when this step type is pro-
grammed. Use this step type only when no mechanical action is
required, as for especially delicate fabrics. Consider chemical con-
centrations, bath time, and liquor temperature when using this
type of step.
4
Intermediate extract 1 (E1): This is low extract speed for H_J, F_
J, V_J, and X_J models. For other models, this is low extract
speed, used for extractions between baths or for final extract at
low speed if machine has two-speed extract.
Programming

Table of Contents