34
Pellerin Milnor Corporation
1
Yes. A signal is required with this chemical injection. The signal
will start when all conditions for the chemical (temperature and/or
level) are satisfied. The actual injection will begin only after the
signal is cancelled, as below.
During normal operation (formula running), this keystroke cancels
the operator signal and allows chemical injection to begin if this
decision is set to 1=Yes.
03 TMMQFFFHC LSCWSS*
01 3
After programming the first chemical, the controller returns to the
first chemical decision to allow the programming of a second
chemical.
0
No additional chemical in this bath. The cursor advances to the
next decision.
3
Chemical 3 (or any other valid chemical number). Cursor advan-
ces to decision W for this chemical.
2.3.3.6.7 Concluding Decisions
BNCJUP03.C19 0000192001 C.2 D.2 D.3 1/2/20 1:16 PM Released
Display or Action Explanation
03 SPD D E
Select the wash speed for this step. The default value is Wash 2
for factory-supplied formulas and new bath steps.
01 x
0
Wash speed 2: Normal wash speed.
1
Wash speed 1: High wash speed for use with goods requiring less
mechanical action. Mechanical action is reduced because the
higher speed reduces the distance the goods are dropped.
2
Alternate wash speed 2: Normal wash speed with the motor on
and off times as set in the alternate on time and alternate off
time configure decisions.
3
Alternate wash speed 1: High wash speed with the motor on and
off (dwell) times as set in the alternate on time and alternate off
time configure decisions.
CAUTION: Machine Malfunction and Damage Hazard — The variable speed inver-
ter used in all single-motor models was programmed at the Milnor factory
for optimum performance with your machine. The constants necessary to
maintain this performance are written inside the electrical box housing the
inverter. Do not enter any values other than those listed for inverter
constants.