42
Pellerin Milnor Corporation
TEMP CONTROL ?
0=NO, 1=YES 1
Select 0=No if this machine is not equipped with steam, cool-
down, or the equipment required to provide or control these op-
tional functions. If 0=No is selected, the next available decision
will be Water Level Units.
Select 1=Yes if this machine is equipped with the necessary valves
and supply piping to perform steaming and/or cooldown, as well
as any necessary electronic boards to control these options.
TEMP UNITS ?
0=°F, 1=°C 0
Select 0=°F to use Fahrenheit as the temperature scale.
Select 1=°C to use Celsius as the temperature scale.
NOTE: This decision appears only if the machine is
configured for temperature control (the value for the Temp
Control decision, above, must be 1).
STEAM ERROR ?
0 = NO STEAM 0
This decision appears only if the machine is configured for tem-
perature control (described above).
Select 0=No Steam if the machine is not equipped for steaming,
as in the case of a machine with temperature control used exclu-
sively for cooldown.
Select from options 1 through 3 if steam is available: 1 = 5 mi-
nutes, 2 = 10 minutes, and 3 = 50 minutes. The number of minutes
selected is the maximum time that the machine will steam in an at-
tempt to achieve the desired temperature before a steam error is
displayed. This self-clearing error does not stop machine opera-
tion. However, for formula steps where the timer is commanded
to stop while steaming until the desired temperature is achieved,
production may be severely restricted by steam errors.
COOLDOWN ERROR ?
0=NO COOLDOWN 0
This decision appears only if the machine is configured, and
equipped with the mechanical and electrical hardware for temper-
ature control (described above).
Select 0=No Cooldown if the machine is not equipped for cool-
down, as in the case of a machine with temperature control used
exclusively for steaming.
Select from options 1 through 3 if cooldown is available: 1 = 5
minutes, 2 = 10 minutes, and 3 = 20 minutes. The number of mi-
nutes selected is the maximum time that the machine will cool-
down in an attempt to achieve the desired temperature before an
error is displayed. The error is self-clearing and does not stop ma-
chine operation. However, production may be severely restricted
by cooldown errors if the cooldown temperature is set lower than
the incoming cold water temperature.
WATER LEVEL UNITS?
0=CM 1=INCHES 1
Select 0=CM to have the water level displayed in centimeters.
Select 1=Inches to display water level in inches.
OFFSET HEIGHT ?
18
This value is set at the Milnor factory to compensate for the height
difference between bottom of the cylinder and the location of the
Programming