USE AND MAINTENANCE MANUAL
31
6.4.1. DOSAGE PARAMETERS
Parameter
Icon
Description
Head type
If selected, the type of dosing group is set to rollers.
If selected, the type of dosing group is set to pump.
Dropping time
Dosing rollers rotation time. Regulates the quantity of
product to be dosed.
Product length
Length of the product to be made.
Dropping speed
Dosing rollers rotation speed. Regulates the quantity of
product to be dosed.
Conveyor speed
Conveyor speed during the dosing phases.
Initial uniformity
Duration of the initial dropping phase carried out with
steady belt and/or nozzles (according to the type of
product selected) to even dosing start.
Final uniformity
Duration of the final dropping phase carried out with
steady belt and/or nozzles (according to the type of
product selected) to even dosing ending.
Dropping speed on final
uniformity
(only drop shape product)
Dosing rollers rotation speed during the final uniformity
phase in drop shape products.
Initial uniformity #2
If the value is different from zero the machine, after
performing the final uniformity, reposition itself at the
beginning of the product and perform a further dosage.

Table of Contents