Model CJV30/TPC Issued 2008.08.04 Revised 2009.06.30 F/W ver. 1.00 Remark
1.1
5.1.6 [MOTOR TEST] Y SERVO MOTOR
Function
Operation test of Y-axis motor is executed.
Operation Procedures
Step Item Description Remarks
1 Speed designation [], []: Selects speed.
Set value: 1 – 1500 mm/s (unit: 1 mm/s)
[], []:
Selection of item 2 – 4
2 Acceleration designation [], []: Selects acceleration.
Set value: 0.05 – 2.00 G (unit: 0.05 G)
3 Moving amount designation [], []: Selects moving amount.
Set value: 1 mm – media length (width) (unit: 1 mm)
4 Cap OFF (Only after media
detection)
5 Test start [ENTER]: Repeats reciprocating motion in the Y direction
with designated conditions.
6 End [END]: Returns to the motion starting position and
executes capping to end the test.
During the test, heater temperature control is allowed. (When [HEATER] key is effective)