© 2009 MIMAKI ENGINEERING CO.,LTD.
5.1.8 P.1
1
2
3
4
5
6
7
8
R.1.0
Maintenance Manual > Test Items > Test Function > [MOTOR TEST] WIPER MOTOR
Model CJV30/TPC Issued 2008.08.04 Revised F/W ver. 1.00 Remark
1.0
Rev.
5.1.8 [MOTOR TEST] WIPER MOTOR
Function
Operation test of wiper motor is executed.
Operation Procedures
Step Item Description Remarks
1 Driving speed designation [], []: Selects driving speed of the motor.
Set value: 100 – 4000 pps (unit: 100 pps)
[], []:
Selection of item 1 – 3
2 WAIT designation [], []: Designates operation interval.
Set value: 0 – 60 sec. (unit: 1 sec.)
3 Count designation [], []: Designates No. of operation.
Set value: CONTINUE, 1 – 1000 count (unit: 1 count)
4 Test start [ENTER]: Drives the motor with designated conditions.
When CONTINUE is selected in count setting,
press [END] to finish the test.
5 End Return the wiper to the original position.