© 2009 MIMAKI ENGINEERING CO.,LTD.
5.1.34 P.1
1
2
3
4
5
6
7
8
R.1.0
Maintenance Manual > Test Items > Test Function > HEAD JOINT
Model CJV30/TPC Issued 2008.08.04 Revised F/W ver. 1.00 Remark
1.0
5.1.34 HEAD JOINT
Purpose
To test if the connection to the print head or the cutter head is normal
Check the operation by repeating the connection operation.
If an error occurs during the connection operation, carry out the test to find out the cause of the error.
Operation sequence of HEAD JOINT test
Relevant errors
No. Item Description Remarks
1 Test start The connection/release operation of the cutter head or the print head is repeated
according to the connection unit that moves right and left. In this case, ON/OFF
operation of this head clamp is also executed.
The connection and lock of the unit is judged by the following:
The right side of main body: Linear encoder
The left side of main body: Light shut-off plate
The number of connections is expressed by COUNT=n.
2 Test end
Error Description Parts to be checked
C-LOCK Error Abnormal standby position of the cutter head • P, C Solenoid
• PR Sensor
P-LOCK Error Abnormal standby position of the print head • P, C Solenoid
• PR Sensor
HEAD JOINT Error Abnormal connection of C head Joint Sensor