Chapter 6 Maintenance
144
1
In LOCAL mode, select [MENU] > [Maintenance], then press the [ENTER] key.
The Maintenance menu is displayed.
2
Select [Station] > [Custody Wash], then press the [ENTER] key.
The carriage moves over the platen.
“Wiper Cleaning Exit Next [ENT]” appears on the display.
3
Open the front cover.
4
Clean the wiper and bracket.
"Wiper Cleaning"(P. 132)
5
Press the [ENTER] key once cleaning is complete.
“Cap Cleaning Completed(Next)[ENT]” appears on the display.
6
Clean the cap rubber.
"Cap Cleaning"(P. 134)
7
Press the [ENTER] key once cleaning is complete.
“Fill the Liquid. Exit Next [ENT]" appears on the display.
8
Fill the cap with washing liquid.
Use a syringe to draw up some washing liquid and fill until it almost overflows from the cap.
9
Press the [ENTER] key.
The print nozzles are washed. “Please wait” appears on the display.
Nozzle washing takes approximately one minute.
Cleaning is performed automatically once print nozzle washing has ended.
“Fill the Liquid. Exit Next [ENT]” appears on the display when print nozzle washing is complete.