6
Nozzle washing
1
Press the key in the local
mode.
2
Select the [MAINTENANCE] by
pressing the or key, and
press the key.
3
Select the [STATION] by pressing the
or key, and press the
key.
4
Select the [MENT:NOZZLE WASH] by
pressing the or key, and
press the key.
• The carriage moves to the center, and the Y-bar moves to the front.
5
Set all the heads to execute washing,
and press the key.
(1) Select the head with or keys.
(2) Select execution (displays the head No.) /non-execution (displays “_”) of the nozzle wash-
ing with or keys.
6
Remove the front cover.
(1) Push the both ends of the front cover.
(2) Pull the cover to the front while opening upward.
• The wiper moves to the front.
• Be sure to put on the supplied goggles and gloves.
Tools
• UJ Cleaning swab (SPC-0386) • Gloves • Goggles
• F-200 / LF-200 Washing Liquid (SPC-0568)